Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

ADSS Cable

ADSS Cable

Home /  Products /  Fiber Optic Cable /  ADSS Cable

All Categorys

Fiber Optic Cable
Management Box
Fiber Optic Connectivity

All Small Categorys

Fiber Optic Cable
Management Box
Fiber Optic Connectivity

The ADSS 100m Span Aerial Optical Fiber Cable Double Jacket 48Cores G.652.D

Model: ADSS-48B1.3-100m-Double

  • Description
Is there a problem? Please contact us to serve you!

Is there a problem? Please contact us to serve you!

Inquiry

Model:

ADSS-48B1.3-100m-Double

Packing:

Wooden Spool

Brand:

OEM

MOQ:

30km

Categories:

ADSS Double Sheath

Delivery time:

5-25 Days

Certificates:

ISO9001

Port of Loading:

SHANGHAI/NINGBO CHINA

Length:

3km/spool

Term of payment:

30%TT as deposit,70%Balance before shipping

Product Description

SOCT Optic Fiber Factory.png

Description:

The ADSS 100m Span Aerial Optical Fiber Cable Double Jacket 48Cores G.652.D for Overhead Use is designed for robust and reliable overhead installations. Featuring a double-jacket, non-metallic self-supporting structure, this cable is built for 100m spans with excellent tensile strength and environmental resilience. Engineered for full-spectrum operation (1260–1625 nm), it supports high-speed data transmission using DWDM and CWDM technologies while ensuring compatibility with 1310 nm devices. Manufactured from certified materials, this product guarantees low splicing loss and high efficiency. With direct factory supply, customizable options, and technical support for project calculations and cable recommendations, it delivers cost-effective and high-performance connectivity for diverse outdoor applications.

Feature:

Application:

1.Durable double-jacket for protection

2.Non-metallic, self-supporting construction

3.High bandwidth DWDM/CWDM compatibility

4.Certified for low splicing loss

5.Strong tensile and environmental resistance

1.FTTH and broadband deployments

2.Power grid communication infrastructure

3.Smart transportation communication systems

4.CATV and computer networking systems

5.Rural and mountainous area networks

Cable Standard

SOCT Cable Systems Products comply with one or several of the following standards.Meanwhile it comply with many other countries'standard

DIN VDE 0888

Telcordia GR-20

DIN VDE 0472

Telcordia GR-409

IEC 60793

GB/T 7424.1-1998

IEC 60794

YD/T 901-2001

IEC 60332

YD/T 1258.1~6,2003-2006

ITU-T G.651 to G.657

YD/T 1997-2009

TIA-EIA 598-B

Optic Color Code

Fiber No.

Color Gode
TIA=EIA 598-B

Symbol

Fiber No.

Color Gode
DIN-VDE 0888

Symbol

1

Blue

BL

1

Red

RD

2

Orange

OR

2

Green

GR

3

Green

GR

3

Blue

BL

4

Brown

BR

4

Yellow

YL

5

Slate

SL

5

White

WH

6

White

WH

6

Slate

SL

7

Red

RD

7

Brown

BR

8

Black

BK

8

Violet

VI

9

Yellow

YL

9

Aqua

AQ

10

Violet

VI

10

Black

BK

11

Rose

RS

11

Orange

OR

12

Aqua

AQ

12

Rose

RS

Note:
TIA-ElA 598-B standard color is used by SOCT for individual fibers or tubes or yarns, unless otherwise specifed.
The color is arranged from NO.1 successively.
Muti fibers per unit up to 24 fibers,fiber number 13 to 24 with black ring.
When order of different fiber types(SM and MM) in one cable,the first color is assigned to the SM fibers and then MM fibers successively.
For the indoor cable,the jacket color of Single Mode Fiber Cabel is Yellow and the Oranger for the Multi-Mode OM1 and OM2 Fiber Cable,and the Aqua for the 50/125 OM3 or OM4 Fiber Cable,unless otherwise specified.

Jacket Material List

Code

Name of Material

Note

1

LSZH

Low smoke zero halogen

2

PE

Polyethylenne(LDPE,MDPE,HDPE)

3

PVC

Polyvinyl Chloride

4

PA(Nylon)

Ployamide

5

TPU

Thermoplastic Urethane

6

FRPE

Flame Retardant Polyethylene

7

TPE

Thermoplastic Elastomer

8

ATPE

Anti-trace Polyethylene

Usually the single-mode ITU-T G652D fiber which can be used at 1310nm and 1550nm wavelength,and has lowattenuation less than 0.22dB/Km is widely used for making the cable for supporting the long-distance networks.In order to meet the development of MAN network, access network and premise local area network(LAN) requirements the ITU-T G652D, G655A/B/C and G657A/B single-mode fibers are also popularly required now.
Multil-mode fiber normally used at 850nm and 1300nm wavelength has high attenuation and small dispersion. It has been mostly applied to the short-distance fiber optic transmission networks because of its limited transmission bandwidth, Multi-mode fiber however has excellent connection coupling efficiency due to its large NA (Numerical Aperture) parameter, 50/125um and 62.5/125um multil-mode fibers are currently widely deployed in LAN system.Meanwhile more and more specialized optical fibers are requested and used for military, transportation control system, new energy and power supply industry.

Optical Fiber Indicate

Optical Fiber Type Description

ITU-T/IEC

Symbol

Single-Mode 9/125 OS1

ITU-T G.652.B,IEC 60793-2-50 B1.1

G652B

Single-Mode 9/125 OS2 Low Water Peak

ITU-T G.652.D,IEC 60793-2-50 B1.3

G652D

Single-Mode 9/125 Non-zero Dispersion Shifted G655C

ITU-T G.655.C/D/E,IEC 60793-2-50-B4_c/d/e

G655C

Single-Mode 9/125 Non-zero Dispersion Shifted G655D

ITU-T G.655.C/D/E,IEC 60793-2-50-B4_c/d/e

G655D

Single-Mode 9/125 Non-zero Dispersion Shifted G655E

ITU-T G.655.C/D/E,IEC 60793-2-50-B4_c/d/e

G655E

Single-Mode 9/125 OS2 Low Water Peak BI.G657A1

ITU-T G.657.A1,IEC 60793-2-50 B6_a1

G657A1

Single-Mode 9/125 OS2 Low Water Peak BI.G657A2

ITU-T G.657.A2,IEC 60793-2-50 B6_a2

G657A2

Single-Mode 9/125 OS2 Low Water Peak BI.G657B3

ITU-T G.657.B3,IEC 60793-2-50 B6_a3

G657B3

Multi-Mode 62.5/125 OM1

IEC 60793-2-10 A1b

OM1

Multi-Mode 50/125 OM2

IEC 60793-2-10 A1a 1 type

OM2

Multi-Mode 50/125 OM3-300 Plus

IEC 60793-2-10 A1a 2 type

OM3

Multi-Mode 50/125 OM3-550 Plus

IEC 60793-2-10 A1a 2 type

OM4

Optical Fiber Environment Capability

Test and Condition

SM Fiber

MM Fiber

Attenuation at Temperature Cycling
a(-60~+85)

≤0.05 dB/Km @1310nm

≤0.1 dB/Km @850nm

≤0.05 dB/Km @1550nm

≤0.1 dB/Km @1300nm

Attenuation at Temperature-humidity Cycling
(-10~+85,98%R.H.)

≤0.05 dB/Km @1310nm

≤0.1 dB/Km @850nm

≤0.05 dB/Km @1550nm

≤0.1 dB/Km @1300nm

Attenuation at water soak Dependence
(23,30 days)

≤0.05 dB/Km @1310nm

≤0.1 dB/Km @850nm

≤0.05 dB/Km @1550nm

≤0.1 dB/Km @1300nm

Attenuation at Damp Heat Dependence
(85,85%R.H.,30 days)

≤0.05 dB/Km @1310nm

≤0.1 dB/Km @850nm

≤0.05 dB/Km @1550nm

≤0.1 dB/Km @1300nm

Characteristics:

G.652.D

G.655

50/125um

62.5/125um

Attenuation

@850nm

-

-

≤3.0 dB/km

≤3.0 dB/km

@1300nm

-

-

≤1.0 dB/km

≤1.0 dB/km

@1310nm

≤0.36 dB/km

≤0.40 dB/km

-

-

@1550nm

≤0.22 dB/km

≤0.23 dB/km

-

-

Bandwidth

@850nm

-

-

≥500 MHz · km

≥200 MHz · km

@1300nm

-

-

≥1000 MHz · km

≥600 MHz · km

Polarization
mode
dispersion

lndividual fibre

≤0.20 ps/√km

≤0.20 ps/√km

-

-

Design link value
(M=20,Q=0.01%)

≤0.1 ps/√km

≤0.1 ps/√km

-

-

Technical parameters:

ADSS 100m span Aerial Optical Fiber Cable Double Jacket 48Cores G.652.D for Overhead Use

Cable fiber count

/

48

Structure

/

1+5

Fiber style

/

G.652D

Central strength member

material

mm

FRP

Diameter (average)

1.5

Loose Tube

Material

mm

PBT

Diameter (average)

2.1

Thickness(average)

0.35

Max fiber/loose tube

12

Tubes color

Full color identification

Fiber excess length

%

0.7~0.8

Water resistance

Material

/

Cable jelly

Inner sehath

material

mm

HDPE

Inner sheath

0.9mm

Non-metallic strengthen components

Material

/

Aramid Yarn

Outer sheath

material

mm

HDPE

Outer sheath

1.8mm

Cable diameter(average)

mm

10.7

Cable weight (Approximate)

kg/km

100

Cable Sectional area

mm2

103.87

Attenuation coefficient(Max)

1310nm

dB/km

0.35

1550nm

0.21

Rated Tensile Strength(RTS)

kn

7

Max allowed tension( MAT)

kn

3.0

Annual average operating tension (EDS)

kn

3.2

Young's modulus

kn/mm2

7.8

Coefficient of thermal expansion

10-6/

9

Crush resistance

Long term

N/100mm

1100

Short term

2200

Permission Bent Radius

static

mm

15 of OD

dynamic

20 of OD

Temperature

When laying

-20~+60

Storage and transportation

-40~+70

runing

-40~+70

Scope of application

Suitable for voltage level under 110kV, wind speed below 25m/s, icing 5mm

Cable Marks

Company Name ADSS-××B1-PE-100M DL/T 788-2001 ××××M Year

Or at customer’s request

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

From start to finish, we ensure quality and care —smooth production, safe delivery!

Custimize Your Needs

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000