SoctFiber 1 x 8 PLC Fiber Optic Cable Splitter Plug-In Module, with a service life of more than 25 years, suitable for CATV, PON network, LAN, etc. This product has uniform light splitting, low insertion loss, Low Polarization Dependent Loss (PDL), and is suitable for Broad Operating Wavelength Range: 1260nm to 1650nm. It supports an operating environment of -40 to 85℃.
1.RoHS Compliant
2.Compact Size Design
3.Outstanding Reliability and Stability
4.Minimal Insertion Loss and Low Polarization Dependent Loss (PDL)
5.Broad Operating Wavelength Range: 1260nm to 1650nm
6.Wide Operating Temperature Range: -20°C to 70°C
Produc name | Fiber Optic PLC Splitter | Packaging: | Carton box |
Delivery Time: | 3-7 working days | Brand Name: | SoctFiber |
Place of Origin: | Jiangsu,China | Model Number: | PLC 1x8 |
Connector: | SC | OEM: | Yes |
Port Configuration | 1x2 | 1x3 | 1x4 | 1x6 | 1x8 | 1x12 | 1x16 | 1x32 | 1x64 |
Insertion Loss (dB) | 4.1 | 6.5 | 7.5 | 10.0 | 10.8 | 12.9 | 13.8 | 17.0 | 21.4 |
Loss Uniformity (dB) | 0.6 | 0.6 | 0.6 | 0.6 | 0.8 | 1.0 | 1.2 | 1.5 | 1.5 |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.4 |
Wavelength Dependent Loss(dB) | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
Temperature Dependent Loss (dB) | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Return Loss (dB) | UPC≥50; APC≥55 | ||||||||
Directivity (dB) | ≥55 | ||||||||
Operating Wavelength (nm) | 1260~1650 | ||||||||
Fiber Type | G657A1 or customer specified | ||||||||
Operating Temperature | -40~+85 | ||||||||
Storage Temperature | -40~+85 |
1x2;1x3;1x4;1x6;1x8 | 100x25x130mm(WxHxL) |
1x12;1x16 | 100x50x130mm(WxHxL) |
1x32 | 100x102x130mm(WxHxL) |
1x64 | 100x200x130mm(WxHxL) |
The insertion loss of PLC Fiber Optic Cable Splitter refers to the dB loss of each output relative to the input light.
The Expression is: IL=-10lg Pouti/Pin
IL=insertion loss of the output port;
Pouti=optical power value of the output port;
Pin=optical power value of the input port.
Additional loss refers to the DB loss of the total optical power of all output ports relative to the input optical power. For fiber couplers, the smaller the additional loss value, the better, which is an important indicator of the production quality. The insertion loss only indicates the output power status of each output port, which not only has the factor of inherent loss, but also takes into account the influence of the splitting ratio. Therefore, the difference in insertion loss between different fiber couplers cannot reflect the quality of device production.
From start to finish, we ensure quality and care —smooth production, safe delivery!