{"id":886,"date":"2026-01-29T04:59:41","date_gmt":"2026-01-29T04:59:41","guid":{"rendered":"https:\/\/soctfiber.com\/?p=886"},"modified":"2026-04-07T06:34:44","modified_gmt":"2026-04-07T06:34:44","slug":"12c-144c-fiber-optical-distribution-frame-odf-high-capacity-fiber-hub","status":"publish","type":"post","link":"https:\/\/soctfiber.com\/pt\/12c-144c-fiber-optical-distribution-frame-odf-high-capacity-fiber-hub\/","title":{"rendered":"12C-144C: distribuidor \u00f3ptico ODF, hub de fibra de alta capacidade"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>1.<\/strong>Ambiente operacional<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temperatura de opera\u00e7\u00e3o: de -25 \u2103 a +55 \u2103<\/li>\n\n\n\n<li>Umidade relativa: \u226493% a +40 \u2103<\/li>\n\n\n\n<li>Condi\u00e7\u00f5es de armazenamento: O produto deve ser armazenado em um dep\u00f3sito bem ventilado e seco, livre de gases corrosivos, a uma temperatura entre -25 \u2103 e +55 \u2103.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>2. Tamanho<\/strong><strong><\/strong><\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"874\" height=\"582\" src=\"http:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub.png\" alt=\"\" class=\"wp-image-887\" srcset=\"https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub.png 874w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-300x200.png 300w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-768x511.png 768w\" sizes=\"auto, (max-width: 874px) 100vw, 874px\" \/><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"4\">Dimens\u00f5es (A x L x P) mm<\/td><td>12 fibras: 45 \u00d7 482 \u00d7 260<\/td><\/tr><tr><td>24 fibras: 45 \u00d7 482 \u00d7 260<\/td><\/tr><tr><td>48 fibras: 90 \u00d7 482 \u00d7 260<\/td><\/tr><tr><td>144 fibras: 270 \u00d7 482 \u00d7 260<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Caracter\u00edsticas<\/strong><strong><\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O uso de bandejas de distribui\u00e7\u00e3o de dupla camada com 24 n\u00facleos pode economizar espa\u00e7o de forma significativa.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"626\" height=\"315\" src=\"http:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-.png\" alt=\"\" class=\"wp-image-888\" srcset=\"https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-.png 626w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub--300x151.png 300w\" sizes=\"auto, (max-width: 626px) 100vw, 626px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Utilizando o m\u00e9todo da fibra de sa\u00edda \u00e0 esquerda<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"320\" src=\"http:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-1-1.png\" alt=\"\" class=\"wp-image-889\" srcset=\"https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-1-1.png 400w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/01\/12C24C48C96C144C-Fiber-Optical-Distribution-Frame-ODF-High-Capacity-Fiber-Hub-1-1-300x240.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Proporcionar termina\u00e7\u00e3o, emenda, armazenamento e gerenciamento eficientes de fibras \u00f3pticas dentro do sistema;<\/li>\n\n\n\n<li>Adote um sistema de gerenciamento de fibras de modo que todas as fibras sejam devidamente encaminhadas e fixadas;<\/li>\n\n\n\n<li>Deve ser instalado e operado exclusivamente por acesso frontal;<\/li>\n\n\n\n<li>O painel de conex\u00f5es do ODF permite f\u00e1cil acesso \u00e0 parte traseira da placa frontal e ao interior do painel;<\/li>\n\n\n\n<li>F\u00e1cil acesso durante a verifica\u00e7\u00e3o e identifica\u00e7\u00e3o de fibras terminadas (por exemplo, pigtails) no ODF;<\/li>\n\n\n\n<li>A instala\u00e7\u00e3o do equipamento ODF \u00e9 feita exclusivamente com ferramentas manuais.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">4. Par\u00e2metros de desempenho \u00f3ptico do conector de fibra \u00f3ptica<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Unidade: dB<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"3\">N\u00e3o.<\/td><td rowspan=\"3\">Nome do item<\/td><td colspan=\"2\">DX (1300 nm)<\/td><td colspan=\"7\">SM (1300 nm\/1550 nm)<\/td><td><\/td><\/tr><tr><td rowspan=\"2\">Perda de inser\u00e7\u00e3o<\/td><td rowspan=\"2\">Perda excedente<\/td><td colspan=\"2\">Perda de inser\u00e7\u00e3o<\/td><td>Perda excedente<\/td><td colspan=\"3\">Perda de retorno<\/td><td>Varia\u00e7\u00e3o na perda de retorno<\/td><td><\/td><\/tr><tr><td>PC\/UPC<\/td><td>APC<\/td><td>&nbsp;<\/td><td>PC<\/td><td>UPC<\/td><td>APC<\/td><td colspan=\"2\">&nbsp;<\/td><\/tr><tr><td>A<\/td><td>Antes da prova<\/td><td>\u22660,35<\/td><td>&nbsp;<\/td><td>\u22660,35<\/td><td>\u22660,45<\/td><td>&nbsp;<\/td><td>\u226740<\/td><td>\u226750<\/td><td>\u226760<\/td><td colspan=\"2\">&nbsp;<\/td><\/tr><tr><td>B<\/td><td>Teste de intercambiabilidade<\/td><td>\u22660,5<\/td><td>&nbsp;<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>&nbsp;<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">&nbsp;<\/td><\/tr><tr><td>C<\/td><td>Durabilidade mec\u00e2nica<\/td><td>\u22660,5<\/td><td>\u22660,2<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,2<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>D<\/td><td>Ensaio de tra\u00e7\u00e3o<\/td><td>\u22660,5<\/td><td>\u22660,1<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,1<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>E<\/td><td>Teste de alta temperatura<\/td><td>\u22660,5<\/td><td>\u22660,2<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,2<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>F<\/td><td>Teste de baixa temperatura<\/td><td>\u22660,5<\/td><td>\u22660,2<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,2<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>G<\/td><td>Teste de calor \u00famido<\/td><td>\u22660,5<\/td><td>\u22660,2<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,2<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>H<\/td><td>Teste de n\u00e9voa salina<\/td><td>\u22660,5<\/td><td>\u22660,2<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,2<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><tr><td>I<\/td><td>Teste de transporte<\/td><td>\u22660,5<\/td><td>\u22660,1<\/td><td>\u22660,5<\/td><td>\u22660,6<\/td><td>\u22660,1<\/td><td>\u226743<\/td><td>\u226748<\/td><td>\u226758<\/td><td colspan=\"2\">\u22665<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">5.<strong>Meta-descri\u00e7\u00f5es para quadros de distribui\u00e7\u00e3o de fibra \u00f3ptica<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>12F - Painel de conex\u00e3o de fibra compacto<\/strong><br>\"Otimize o gerenciamento de fibras com nosso quadro de distribui\u00e7\u00e3o \u00f3ptica de 12 fibras \u2014 compacto, dur\u00e1vel e ideal para redes de fibra em pequena escala. Perfeito para conex\u00f5es e termina\u00e7\u00e3o eficientes de fibras.\"<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>24F - Solu\u00e7\u00e3o de ODF de alta densidade<\/strong><br>\"Melhore a conectividade de fibra \u00f3ptica com nosso Quadro de Distribui\u00e7\u00e3o \u00d3ptica (ODF) de 24 fibras. Projetado para ambientes de alta densidade, este ODF garante uma organiza\u00e7\u00e3o perfeita das fibras e um desempenho confi\u00e1vel.\"<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>48F - Gerenciamento escal\u00e1vel de fibra \u00f3ptica<\/strong><br>\"Obtenha um gerenciamento de fibra escal\u00e1vel com nosso quadro de distribui\u00e7\u00e3o \u00f3ptica de 48 fibras. Projetado para redes em expans\u00e3o, ele oferece roteamento de fibra de alto desempenho e organiza\u00e7\u00e3o eficiente dos cabos.\"<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>96F - Termina\u00e7\u00e3o eficiente de fibra \u00f3ptica<\/strong><br>\"Maximize a efici\u00eancia com nosso quadro de distribui\u00e7\u00e3o \u00f3ptica de 96 fibras. Projetado para implanta\u00e7\u00f5es em grande escala, ele oferece solu\u00e7\u00f5es simplificadas de termina\u00e7\u00e3o de fibras e cabeamento estruturado.\"<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>144F - Hub de fibra \u00f3ptica de alta capacidade<\/strong><br>\"Atualize sua rede com nosso quadro de distribui\u00e7\u00e3o de fibra \u00f3ptica de 144 fibras \u2014 ideal para centros de dados e hubs de telecomunica\u00e7\u00f5es. Desfrute de capacidade de fibra superior, organiza\u00e7\u00e3o e expans\u00e3o sem interrup\u00e7\u00f5es.\"<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Perguntas frequentes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Quais s\u00e3o as capacidades de fibra dispon\u00edveis em um quadro de distribui\u00e7\u00e3o de fibra \u00f3ptica (ODF)?<\/strong><br>As op\u00e7\u00f5es comuns de capacidade incluem 12C, 24C, 48C, 96C e 144C, permitindo que os compradores adaptem o espa\u00e7o no gabinete, o n\u00famero de fibras e os requisitos de expans\u00e3o do projeto de maneira mais eficiente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Por que os compradores optam por um hub de fibra ODF com v\u00e1rias capacidades para racks de telecomunica\u00e7\u00f5es?<\/strong><br>Um hub de fibra ODF com v\u00e1rias capacidades oferece maior flexibilidade para diferentes disposi\u00e7\u00f5es de rack e escalas de rede, o que facilita o planejamento tanto para a instala\u00e7\u00e3o atual quanto para futuras expans\u00f5es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Quais s\u00e3o as vantagens do projeto de quadro de distribui\u00e7\u00e3o de fibra \u00f3ptica com acesso frontal?<\/strong><br>Um quadro de distribui\u00e7\u00e3o de fibra \u00f3ptica com acesso frontal torna a instala\u00e7\u00e3o, a inspe\u00e7\u00e3o, o conexionamento e a manuten\u00e7\u00e3o de rotina mais convenientes, especialmente em racks de telecomunica\u00e7\u00f5es onde o acesso traseiro \u00e9 limitado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Um ODF montado em rack pode suportar a termina\u00e7\u00e3o, a emenda e o armazenamento de fibras em uma \u00fanica unidade?<\/strong><br>Sim. Um ODF montado em rack pode integrar fun\u00e7\u00f5es de termina\u00e7\u00e3o, emenda, armazenamento e gerenciamento de fibra em um \u00fanico conjunto, ajudando a manter o roteamento interno mais organizado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. Qual estrutura de bandeja \u00e9 comumente utilizada em um quadro de distribui\u00e7\u00e3o \u00f3ptica de alta capacidade?<\/strong><br>Um quadro de distribui\u00e7\u00e3o \u00f3ptica de alta capacidade costuma utilizar bandejas de fibra multicamadas ou de camada dupla para melhorar a organiza\u00e7\u00e3o interna e permitir um gerenciamento de fibra com maior densidade.<\/p>","protected":false},"excerpt":{"rendered":"<p>1.Operating environment 2.Size Dimension (H x W x D) mm 12 Fibers:45\u00d7482\u00d7260 24&nbsp;Fibers:45\u00d7482\u00d7260 48 Fibers:90\u00d7482\u00d7260 144&nbsp;Fibers:270\u00d7482\u00d7260 3.Features 4.Optical performance parameters of fiber optic connector &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Unit\uff1adB No. Item Name DX\uff081300nm) SM( 1300nm\/1550nm) Insertion loss Excess loss Insertion loss Excess loss Return loss Change in return loss PC\/UPC APC &nbsp; PC UPC APC &nbsp; A Before the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":894,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,8,25],"tags":[],"class_list":["post-886","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","category-fiber-management-box","category-optical-distribution-frame"],"_links":{"self":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/886","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/comments?post=886"}],"version-history":[{"count":3,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/886\/revisions"}],"predecessor-version":[{"id":1485,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/886\/revisions\/1485"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/media\/894"}],"wp:attachment":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/media?parent=886"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/categories?post=886"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/tags?post=886"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}