{"id":1065,"date":"2026-03-02T04:52:15","date_gmt":"2026-03-02T04:52:15","guid":{"rendered":"https:\/\/soctfiber.com\/?p=1065"},"modified":"2026-03-12T08:43:51","modified_gmt":"2026-03-12T08:43:51","slug":"mtp-to-mtp-upc-8-12-16-24-fibers-om4","status":"publish","type":"post","link":"https:\/\/soctfiber.com\/pt\/mtp-to-mtp-upc-8-12-16-24-fibers-om4\/","title":{"rendered":"MTP UPC(F\/M) para MTP UPC(F\/M), 8,12,16,24 fibras multimodo (OM4), 0.35dB m\u00e1x., tipo A\/B"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Especifica\u00e7\u00f5es<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><tbody><tr><td>Conector A<\/td><td>MTP f\u00eamea<\/td><\/tr><tr><td>Conector B<\/td><td>MTP f\u00eamea<\/td><\/tr><tr><td>Tipo de polimento<\/td><td>UPC para UPC<\/td><\/tr><tr><td>Modo de fibra<\/td><td>OM4 50\/125 \u00b5m<\/td><\/tr><tr><td>Contagem de fibras<\/td><td>8, 12, 16, 24 fibras<\/td><\/tr><tr><td>Tipo de fibra de vidro<\/td><td>Fibra de baixa sensibilidade \u00e0s perdas por curvatura<\/td><\/tr><tr><td>Comprimento de onda<\/td><td>850\/1300 nm<\/td><\/tr><tr><td>Polaridade<\/td><td>Tipo A\/B<\/td><\/tr><tr><td>Di\u00e2metro externo (DE) do cabo<\/td><td>3,0 mm<\/td><\/tr><tr><td>Revestimento do cabo<\/td><td>Plen\u00e1rio (OFNP)<\/td><\/tr><tr><td>Raio m\u00ednimo de curvatura (fibra \u00f3ptica)<\/td><td>7,5 mm<\/td><\/tr><tr><td>Raio m\u00ednimo de curvatura (cabo de fibra \u00f3ptica)<\/td><td>20\/10D (Din\u00e2mico\/Est\u00e1tico)<\/td><\/tr><tr><td>Durabilidade do conector<\/td><td>500 vezes<\/td><\/tr><tr><td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/td><td>80\/240N (Longo\/Curto Prazo)<\/td><\/tr><tr><td>Perda de inser\u00e7\u00e3o<\/td><td>\u22640,35 dB (0,15 dB t\u00edpico)<\/td><\/tr><tr><td>Perda de retorno<\/td><td>\u226520 dB<\/td><\/tr><tr><td>Atenua\u00e7\u00e3o a 850 nm<\/td><td>\u22642,3 dB\/km<\/td><\/tr><tr><td>Atenua\u00e7\u00e3o a 1300 nm<\/td><td>\u22640,6 dB\/km<\/td><\/tr><tr><td>Temperatura de opera\u00e7\u00e3o<\/td><td>-10 a 60 \u00b0C (14 a 140 \u00b0F)<\/td><\/tr><tr><td>Temperatura de armazenamento<\/td><td>-10 a 70 \u00b0C (14 a 158 \u00b0F)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Solu\u00e7\u00f5es de conectividade<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"http:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-1024x576.webp\" alt=\"\" class=\"wp-image-1067\" srcset=\"https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-1024x576.webp 1024w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-300x169.webp 300w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-768x432.webp 768w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-1536x864.webp 1536w, https:\/\/soctfiber.com\/wp-content\/uploads\/2026\/03\/24-fiber-MTP-OM4-jumper-cable-for-40Gbps-connections-1-2048x1152.webp 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conex\u00e3o de 40 Gbps<\/strong>:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A porta QSFP+ do switch est\u00e1 equipada com um m\u00f3dulo \u00f3ptico de 850 nm, utilizando um cabo de conex\u00e3o MTP de 12 fibras com&nbsp;<strong>transmiss\u00e3o bidirecional por uma \u00fanica fibra<\/strong>, para atender aos requisitos de acesso \u00e0 Ethernet de 40G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conex\u00e3o de 100 Gbps<\/strong>:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A porta QSFP28 do switch est\u00e1 equipada com um m\u00f3dulo \u00f3ptico de 850 nm, utilizando um cabo de conex\u00e3o MTP de 24 fibras para implementar&nbsp;<strong>Agrega\u00e7\u00e3o de links de backbone de 100G<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conex\u00e3o de 200 Gbps<\/strong>:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A porta QSFP-DD do switch est\u00e1 equipada com um m\u00f3dulo \u00f3ptico duplo, utilizando um cabo de conex\u00e3o MTP de 24 fibras para alcan\u00e7ar&nbsp;<strong>Transmiss\u00e3o de alt\u00edssima velocidade de 200G<\/strong>&nbsp;por meio da multiplexa\u00e7\u00e3o por divis\u00e3o de comprimento de onda (WDM).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Principais caracter\u00edsticas<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Fibra multimodo OM4<\/strong>: Fibra multimodo otimizada para laser de 50\/125 \u00b5m, compat\u00edvel com Ethernet 10G\/40G\/100G\/200G\/400G em dist\u00e2ncias de at\u00e9 100 m (100G SR4)<\/li>\n\n\n\n<li><strong>Conector MTP\u00ae<\/strong>: Compat\u00edvel com US Conec MTP\u00ae, configura\u00e7\u00e3o f\u00eamea-f\u00eamea, polimento UPC<\/li>\n\n\n\n<li><strong>Baixa perda de inser\u00e7\u00e3o<\/strong>: IL m\u00e1ximo \u2264 0,35 dB por jumper, garantindo conex\u00f5es est\u00e1veis de alta velocidade<\/li>\n\n\n\n<li><strong>Fibra de baixa sensibilidade \u00e0s perdas por curvatura<\/strong>: Raio m\u00ednimo de curvatura de 7,5 mm, reduz a perda de sinal durante a instala\u00e7\u00e3o e o tra\u00e7ado<\/li>\n\n\n\n<li><strong>Alta densidade<\/strong>: Dispon\u00edvel em configura\u00e7\u00f5es de 12\/24 fibras, ideal para ambientes com espa\u00e7o limitado<\/li>\n\n\n\n<li><strong>Codificado por cores<\/strong>: Revestimento azul-turquesa (cor padr\u00e3o OM4) para facilitar a identifica\u00e7\u00e3o em sistemas de cabeamento<\/li>\n\n\n\n<li><strong>Op\u00e7\u00f5es de fia\u00e7\u00e3o<\/strong>: Compat\u00edvel com a polaridade Tipo A e Tipo B para uma implanta\u00e7\u00e3o flex\u00edvel<\/li>\n\n\n\n<li><strong>Projeto pr\u00e9-terminado<\/strong>: Terminado e testado na f\u00e1brica, reduz o tempo de instala\u00e7\u00e3o no local e minimiza erros<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Aplica\u00e7\u00f5es t\u00edpicas<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cabo para data center de alta densidade<\/li>\n\n\n\n<li>Interconex\u00e3o de clusters de computa\u00e7\u00e3o com IA\/GPU<\/li>\n\n\n\n<li>Uplinks de 40G\/100G para servidores e switches<\/li>\n\n\n\n<li>Arquitetura de rede Leaf-Spine<\/li>\n\n\n\n<li>Sistemas de cabeamento de backbone e horizontal pr\u00e9-terminados<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Specifications Connector A MTP Female Connector B MTP Female Polish Type UPC to UPC Fiber Mode OM4 50\/125\u00b5m Fiber Count 8, 12, 16, 24 Fibers Glass Fiber Type Bend Insensitive Fiber Wavelength 850\/1300nm Polarity Type A\/B Cable Outside Diameter (OD) 3.0mm Cable Jacket Plenum (OFNP) Min. Bend Radius (Optical Fiber) 7.5mm Min. Bend Radius (Fiber [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1068,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,7,19],"tags":[],"class_list":["post-1065","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","category-fiber-optic-connectivity","category-mtp-mpo-fiber-cable"],"_links":{"self":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/1065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/comments?post=1065"}],"version-history":[{"count":4,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/1065\/revisions"}],"predecessor-version":[{"id":1192,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/posts\/1065\/revisions\/1192"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/media\/1068"}],"wp:attachment":[{"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/media?parent=1065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/categories?post=1065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/soctfiber.com\/pt\/wp-json\/wp\/v2\/tags?post=1065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}