    MTP-16 to 2x MTP-8 OS2 Breakout Cable

    Classification:Products

    This MTP-16 APC female to 2x MTP-8 APC female breakout cable is designed for single-mode breakout links in high-density data center cabling. It uses 16-fiber OS2 single-mode fiber with crossover polarity to connect one MTP-16 interface to two MTP-8 interfaces, making it suitable for 800G to 2x400G optical breakout applications where low loss, stable polarity mapping, and compact cabling are important.

    Details Introduction

    This breakout cable is intended for structured single-mode cabling where one 16-fiber link must be split into two 8-fiber links without using a separate breakout cassette. It is suitable for high-density optical interconnect environments where lower insertion loss, simpler cable management, and direct breakout connectivity are preferred.

    The cable uses MTP-16 APC female on one end and 2x MTP-8 APC female on the other, with OS2 9/125μm G.657.A1 bend-insensitive fiber, crossover polarity, 3.0 mm outer diameter, and 0.5 m breakout length. The listed optical performance includes 0.35 dB maximum insertion loss, 0.15 dB typical insertion loss, and return loss of at least 65 dB. The page also lists 1310 nm and 1550 nm operating wavelengths, 10 mm minimum bend radius, and OFNP plenum jacket.

    For data center buyers comparing breakout options, the main selection points usually include connector type, polarity, transceiver mapping, insertion loss, fiber type, jacket rating, and whether a direct breakout cable is more suitable than a cassette-based solution. This structure is especially useful when one 800G link needs to be split into two 400G links in a compact cabling environment.

    Key Features

    • MTP-16 APC female to 2x MTP-8 APC female breakout structure
    • OS2 9/125μm single-mode fiber
    • G.657.A1 bend-insensitive fiber
    • Crossover polarity for breakout mapping
    • 0.35 dB maximum insertion loss
    • Return loss of at least 65 dB
    • OFNP plenum jacket
    • Suitable for 800G to 2x400G optical breakout links

    Product Description

    This MTP-16 to 2x MTP-8 OS2 breakout cable is a practical choice for high-speed optical links that require direct breakout connectivity without adding cassette hardware. In dense cabling systems, this can help reduce connection points and simplify link structure while keeping fiber mapping clear for transceiver breakout use.

    The APC female connector format is suitable for single-mode optical systems that require lower back reflection, while G.657.A1 fiber helps improve routing flexibility in tighter cabling paths. The listed yellow OFNP jacket also matches standard single-mode identification and supports plenum installation requirements.

    For projects building 800G to 2x400G links, this cable is suitable when the transceiver and polarity design require direct MTP-16 to dual MTP-8 connectivity. In related single-mode cabling applications, it can also be evaluated alongside single mode fiber patch cord products and G.657.A1 single mode fiber pages when comparing cable structure and routing requirements.

    Typical Applications

    • 800G to 2x400G breakout links
    • High-density single-mode data center cabling
    • MTP trunk to breakout interconnection
    • Direct breakout alternative to cassette-based links
    • Plenum-rated optical cabling environments

    How to Choose the Right Breakout Cable

    Choose this structure when the link requires one MTP-16 interface to break out into two MTP-8 interfaces.

    Choose APC female connectors when the optical system uses single-mode APC mating interfaces and lower back reflection is required.

    Confirm crossover polarity before ordering so the cable matches the intended transceiver mapping and link architecture.

    Confirm OFNP jacket requirement when the installation includes plenum spaces or building cabling areas that require plenum-rated fiber cable.

    Technical Specifications

    ItemSpecification
    Product TypeMTP Breakout Cable
    Connector AMTP-16 Female APC with Offset Key
    Connector B2x MTP-8 Female APC
    Fiber ModeOS2 9/125μm Single Mode
    Glass FiberG.657.A1 Bend Insensitive Fiber
    Wavelength1310/1550nm
    PolarityCrossover
    Insertion Loss0.35dB Max (0.15dB Typ.)
    Return Loss≥65dB
    Cable JacketOFNP Plenum, Yellow
    Minimum Bend Radius10mm
    Cable OD3.0mm
    Breakout Length0.5m
    Installation Tensile Load66N
    Tensile Strength60N Long Term / 120N Short Term
    Operating Temperature-10°C to 60°C
    Storage Temperature-10°C to 70°C
    ComplianceIEC 61754-7, ANSI/TIA-604-5, ANSI/TIA-568.3-D

    Connectivity and Deployment Notes

    This cable is suitable for 800G QSFP-DD to dual 400G QSFP-DD or OSFP breakout connectivity where the link design uses 16 fibers on the trunk side and 8 fibers on each breakout side. It is also positioned as a direct breakout alternative to separate breakout cassettes in dense single-mode cabling systems.

    CTA

    Looking for an MTP-16 to 2x MTP-8 OS2 breakout cable supplier for 800G to 2x400G links? Send us your connector type, polarity requirement, cable length, jacket requirement, and quantity. We will help match the suitable breakout cable configuration for your application and provide a quotation based on your project requirement.

    FAQ

    Which transceivers use MTP-16 to 2x MTP-8 OS2 breakout cable?

    This cable is suitable for link structures that require one 16-fiber interface to break out into two 8-fiber interfaces, including 800G QSFP-DD to dual 400G QSFP-DD or OSFP connectivity.

    Is MTP-16 to 2x MTP-8 cable used for 800G to 2x400G breakout?

    Yes. This structure is designed for 800G to 2x400G optical breakout links where one 16-fiber trunk is divided into two 8-fiber branches.

    Should breakout cable or breakout cassette be used for 800G to 400G links?

    A breakout cable is generally more suitable when direct connectivity, fewer connection points, and lower link complexity are preferred. A cassette may be more suitable when the cabling design requires modular patching architecture.

    What polarity is required for MTP-16 to 2x MTP-8 OS2 breakout cable?

    This product uses crossover polarity, so polarity should be confirmed against the intended transceiver mapping and link design before ordering.

    Why use APC female connectors for this single-mode breakout cable?

    APC female connectors are suitable for single-mode optical systems that require lower back reflection and compatible mating with APC optical interfaces.

    Is G.657.A1 fiber important for breakout cable routing?

    Yes. G.657.A1 bend-insensitive fiber helps improve routing flexibility in tighter cabling paths and high-density installation environments.